The analysis of long-term borehole heat exchanger system exploitation

  • Marek Jaszczur
  • Tomasz Śliwa

Abstract

The key issue in designing borehole heat exchangers (BHE) is the long-term performance of the ground source heat pump (GSHP) systems. The performance directly reflects economic profitability and depends on a large number of parameters including rock formation, the construction of the borehole heat exchangers, working parameters (circulation rates) and thermal load. The objective of the paper is to perform a realistic long-term (up to 10 years) analysis of the ground system to show possible degradation of efficiency over time. A mathematical model of the heat transfer in a borehole heat exchanger and the surrounding area has been constructed for parameters of the currently running experimental system. The long-term performance of the ground source heat pump system is evaluated.

Keywords

borehole heat exchangers, reservoir engineering, heat pumps systems, geoenergetics,

References

Published
Jan 25, 2017
How to Cite
JASZCZUR, Marek; ŚLIWA, Tomasz. The analysis of long-term borehole heat exchanger system exploitation. Computer Assisted Methods in Engineering and Science, [S.l.], v. 20, n. 3, p. 227-235, jan. 2017. ISSN 2956-5839. Available at: <https://cames.ippt.gov.pl/index.php/cames/article/view/68>. Date accessed: 03 dec. 2024.
Section
Articles